10-11
Configuring for Network Management Applications
Using SNMP Tools To Manage the Switch
For example, to configure a trap receiver in a community named "red-team"
with an IP address of 10.28.227.130 to receive only "critical" log messages:
HPswitch(config)# snmp-server trap-receiver red-team
10.28.227.130 critical
Notes To replace one community name with another for the same IP address, you
must use no snmp-server host < community-name> < ip-address > to delete the
unwanted community name. Otherwise, adding a new community name with
an IP address already in use with another community name simply creates
two allowable community name entries for the same management station.
If you do not specify the event level ([<none | all | non-info | critical | debug>])
then the switch does not send event log messages as traps. “Well-Known” traps
and threshold traps (if configured) will still be sent.
Using the CLI To Enable Authentication Traps
Note For this feature to operate, one or more trap receivers must be configured on
the switch. See “In the default configuration, there are no trap receivers
configured, and the authentication trap feature is disabled. From the CLI you
can configure up to ten SNMP trap receivers to receive SNMP traps from the
switch. As an option, you can also configure the switch to send Event Log
messages as traps. CLI: Configuring and Displaying Trap Receivers” on page
10-8.
Using the CLI To Enable Authentication Traps.
For example:
HPswitch(config)# snmp-server enable traps authentication
Check the Event Log in the console interface to help determine why the
authentication trap was sent. (Refer to “Using the Event Log To Identify
Problem Sources” on page C-21.)
Syntax: [no] snmp-server enable traps authentication
Enables or disables sending an authentication trap to
the configured trap receiver(s) if an unauthorized
management station attempts to access the switch.
!Software.book Page 11 Thursday, October 10, 2002 6:10 PM

Table of Contents

Other manuals for HP ProCurve 2650

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP ProCurve 2650 and is the answer not in the manual?

HP ProCurve 2650 Specifications

General IconGeneral
Switching Capacity13.6 Gbps
Forwarding Rate10.1 Mpps
Layer2
Jumbo Frame SupportYes
Form FactorRack-mountable
VLAN SupportYes
Layer 3 RoutingNo
PoE SupportNo
FanlessNo
AltitudeUp to 3, 000 meters
ManagementCLI, SNMP
Operating Temperature0°C to 50°C
Storage Temperature-40°C to 70°C
Humidity15% to 95% non-condensing

Related product manuals