EasyManuals Logo

HP ProCurve 2650 User Manual

HP ProCurve 2650
524 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #247 background imageLoading...
Page #247 background image
11-9
Port-Based Virtual LANs (VLANs) and GVRP
Port-Based Virtual LANs (Static VLANs)
General Steps for Using VLANs
1. Plan your VLAN strategy and create a map of the logical topology that will
result from configuring VLANs. Include consideration for the interaction
between VLANs and other features such as Spanning Tree Protocol, load
balancing, and IGMP. (Refer to “Effect of VLANs on Other Switch Fea-
tures” on page 11-30.) If you plan on using dynamic VLANs, include the
port configuration planning necessary to support this feature. (See
“GVRP” on page 11-33.)
By default, VLAN support is enabled and the switch is configured for eight
VLANs.
2. Configure at least one VLAN in addition to the default VLAN.
3. Assign the desired switch ports to the new VLAN(s).
4. If you are managing VLANs with SNMP in an IP network, each VLAN must
have an IP address. Refer to “IP Configuration” on page 7-3.
Notes on Using VLANs
If you are using DHCP/Bootp to acquire the switch’s configuration, packet
time-to-live, and TimeP information, you must designate the VLAN on
which DHCP is configured for this purpose as the primary VLAN. (In the
factory-default configuration, the DEFAULT_VLAN is the primary VLAN.)
IGMP, and some other features operate on a “per VLAN” basis. This means
you must configure such features separately for each VLAN in which you
want them to operate.
You can rename the default VLAN, but you cannot change its VID (1) or
delete it from the switch.
Any ports not specifically assigned to another VLAN will remain assigned
to the DEFAULT_VLAN.
To delete a VLAN from the switch, you must first remove from that VLAN
any ports assigned to it.
Changing the number of VLANs supported on the switch requires a reboot.
Other VLAN configuration changes are dynamic.
!Software.book Page 9 Thursday, October 10, 2002 6:10 PM

Table of Contents

Other manuals for HP ProCurve 2650

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP ProCurve 2650 and is the answer not in the manual?

HP ProCurve 2650 Specifications

General IconGeneral
Switching Capacity13.6 Gbps
Forwarding Rate10.1 Mpps
Layer2
Jumbo Frame SupportYes
Form FactorRack-mountable
VLAN SupportYes
Layer 3 RoutingNo
PoE SupportNo
FanlessNo
AltitudeUp to 3, 000 meters
ManagementCLI, SNMP
Operating Temperature0°C to 50°C
Storage Temperature-40°C to 70°C
Humidity15% to 95% non-condensing

Related product manuals