11-29
Port-Based Virtual LANs (VLANs) and GVRP
Port-Based Virtual LANs (Static VLANs)
HPswitch (config)# management-vlan 100
HPswitch (config)# vlan 100 tagged a1
HPswitch (config)# vlan 100 tagged a2
Deleting the Management VLAN. You can disable the Secure Manage-
ment feature without deleting the VLAN itself. For example, either of the
following commands disables the Secure Management feature in the above
example:
HPswitch (config)# no management-vlan 100
HPswitch (config)# no management-vlan my_vlan
Operating Notes for Management VLANs
Only one Management-VLAN can be active in the switch. If one Manage-
ment-VLAN VID is saved in the startup-config file and you configure a
different VID in the running-config file, the switch uses the running-config
version until you either use the write-memory command or reboot the
switch.
During a Telnet session to the switch, if you configure the Management-
VLAN to a VID that excludes the port through which you are connected
to the switch, you will continue to have access only until you terminate
the session by logging out or rebooting the switch.
During a web browser session to the switch, if you configure the Manage-
ment-VLAN to a VID that excludes the port through which you are
connected to the switch, you will continue to have access only until you
close the browser session or rebooting the switch.
Note The Management-VLAN feature does not control management access through
a direct connection to the switch’s serial port.
Enabling Spanning Tree where there are multiple links using separate
VLANs, including the Management VLAN, between a pair of switches,
Spanning Tree will force the blocking of one or more links. This may
include the link carrying the Management VLAN, which will cause loss of
management access to some devices.
!Software.book Page 29 Thursday, October 10, 2002 6:10 PM

Table of Contents

Other manuals for HP ProCurve 2650

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP ProCurve 2650 and is the answer not in the manual?

HP ProCurve 2650 Specifications

General IconGeneral
Switching Capacity13.6 Gbps
Forwarding Rate10.1 Mpps
Layer2
Jumbo Frame SupportYes
Form FactorRack-mountable
VLAN SupportYes
Layer 3 RoutingNo
PoE SupportNo
FanlessNo
AltitudeUp to 3, 000 meters
ManagementCLI, SNMP
Operating Temperature0°C to 50°C
Storage Temperature-40°C to 70°C
Humidity15% to 95% non-condensing