12-7
Multimedia Traffic Control with IP Multicast (IGMP)
CLI: Configuring and Displaying IGMP
Viewing the Current IGMP Configuration. This command lists the IGMP
configuration for all VLANs configured on the switch or for a specific VLAN.
Syntax: show ip igmp config IGMP configuration for all
VLANs on the switch
show ip igmp vlan <vid> config IGMP configuration for a
specific VLAN on the switch,
including per-port data
(For IGMP operating status, see Internet Group Management Protocol
(IGMP) Status on page B-19.)
For example, suppose you have the following VLAN and IGMP configurations
on the switch:
You could use the CLI to display this data as follows:
Figure 12-1. Example Listing of IGMP Configuration for All VLANs in the Switch
The following version of the show ip igmp command includes the VLAN ID (vid)
designation, and combines the above data with the IGMP per-port configura-
tion:
VLAN ID VLAN Name IGMP
Enabled
Forward with
High Priority
Querier
1 DEFAULT_VLAN Yes No No
22 VLAN-2 Yes Yes Yes
33 VLAN-3 No No No
!Software.book Page 7 Thursday, October 10, 2002 6:10 PM

Table of Contents

Other manuals for HP ProCurve 2650

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP ProCurve 2650 and is the answer not in the manual?

HP ProCurve 2650 Specifications

General IconGeneral
Switching Capacity13.6 Gbps
Forwarding Rate10.1 Mpps
Layer2
Jumbo Frame SupportYes
Form FactorRack-mountable
VLAN SupportYes
Layer 3 RoutingNo
PoE SupportNo
FanlessNo
AltitudeUp to 3, 000 meters
ManagementCLI, SNMP
Operating Temperature0°C to 50°C
Storage Temperature-40°C to 70°C
Humidity15% to 95% non-condensing

Related product manuals