Multimedia Traffic Control with IP Multicast (IGMP)
How IGMP Operates
3. Enter either of the following walkmib command options:
walkmib hpSwitchIgmpPortForcedLeaveState
- OR -
walkmib 1.3.6.1.4.1.11.2.14.11.5.1.7.1.15.3.1.5
The resulting display lists the Forced Fast-Leave state for all ports in the
switch, by VLAN. (A port belonging to more than one VLAN will be listed
once for each VLAN, and if multiple VLANs are not configured, all ports
will be listed as members of the default VLAN.) The following command
produces a listing such as that shown in figure 12-4:
Figure 12-4. Example of a Forced Fast-Leave Listing where all Ports are Members of the Default VLAN
To List the Forced Fast-Leave State for a Single Port. (See the Note
on VLAN Numbers on page 12-15.)
Go to the switchs command prompt and use the
getmib command, as shown
below.
Syntax:
getmib hpSwitchIgmpPortForcedLeaveState.<vlan number>
<.port number>
- OR -
getmib 1.3.6.1.4.1.11.2.14.11.5.1.7.1.15.3.1.5.<vlan number>
<.port number>
For example, the following command to list the state for port A6 (which,
in this case, belongs to the default VLAN) produces the indicated listing:
The 2 at the end of a port
listing shows that Forced
Fast-Leave is disabled on
the corresponding port.
The
1 at the end of a port
listing shows that Forced
Fast-Leave is enabled on
the corresponding port.
Ports 1-6: 6- Port 109/1000T Module in Slot A
Internal VLAN Number for the Default VLAN
Note: Internal VLAN numbers reflect the sequence
in which VLANs are created, and are not related to
the unique VID assigned to each VLAN. (See the
Note on VLAN Numbers on page 12-15.)
Sequential Port
Numbers
!Software.book Page 16 Thursday, October 10, 2002 6:10 PM

Table of Contents

Other manuals for HP ProCurve 2650

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP ProCurve 2650 and is the answer not in the manual?

HP ProCurve 2650 Specifications

General IconGeneral
Switching Capacity13.6 Gbps
Forwarding Rate10.1 Mpps
Layer2
Jumbo Frame SupportYes
Form FactorRack-mountable
VLAN SupportYes
Layer 3 RoutingNo
PoE SupportNo
FanlessNo
AltitudeUp to 3, 000 meters
ManagementCLI, SNMP
Operating Temperature0°C to 50°C
Storage Temperature-40°C to 70°C
Humidity15% to 95% non-condensing