EasyManuals Logo

HP ProCurve 2650 User Manual

HP ProCurve 2650
524 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #94 background imageLoading...
Page #94 background image
5-6
Switch Memory and Configuration
Using the CLI To Implement Configuration Changes
For example, the default port mode setting is auto. Suppose that your network
uses Cat 3 wiring and you want to connect the switch to another autosensing
device capable of 100 Mbps operation. Because 100 Mbps over Cat 3 wiring
can introduce transmission problems, the recommended port mode is
auto-10,
which allows the port to negotiate full- or half-duplex, but restricts speed to
10 Mbps. The following command configures port A5 to auto-10 mode in the
running-config file, allowing you to observe performance on the link without
making the mode change permanent.
HPswitch(config)# interface e a5 speed-duplex auto-10
After you are satisfied that the link is operating properly, you can save the
change to the switch’s permanent configuration (the startup-config file) by
executing the following command:
HPswitch(config)# write memory
The new mode (
auto-10) on port A5 is now saved in the startup-config file, and
the startup-config and running-config files are identical. If you subsequently
reboot the switch, the
auto-10 mode configuration on port A5 will remain
because it is included in the startup-config file.
How To Cancel Changes You Have Made to the Running-Config File.
If you use the CLI to change parameter settings in the running-config file, and
then decide that you don’t want those changes to remain, you can use either
of the following methods to remove them:
Manually enter the earlier values you had for the changed settings. (This
is recommended if you want to restore a small number of parameter
settings to their previous boot-up values.)
Update the running-config file to match the startup-config file by reboot-
ing the switch. (This is recommended if you want to restore a larger
number of parameter settings to their previous boot-up values.)
If you use the CLI to change a parameter setting, and then execute the boot
command without first executing the
write memory command to save the
change, the switch prompts you to specify whether to save the changes in the
current running-config file. For example:
!Software.book Page 6 Thursday, October 10, 2002 6:10 PM

Table of Contents

Other manuals for HP ProCurve 2650

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP ProCurve 2650 and is the answer not in the manual?

HP ProCurve 2650 Specifications

General IconGeneral
Switching Capacity13.6 Gbps
Forwarding Rate10.1 Mpps
Layer2
Jumbo Frame SupportYes
Form FactorRack-mountable
VLAN SupportYes
Layer 3 RoutingNo
PoE SupportNo
FanlessNo
AltitudeUp to 3, 000 meters
ManagementCLI, SNMP
Operating Temperature0°C to 50°C
Storage Temperature-40°C to 70°C
Humidity15% to 95% non-condensing

Related product manuals