Page #223 background imageLoading...
Page #223 background image
213
Field Description
Type
Prefix type:
• Static—Static IPv6 prefix.
• Dynamic—Dynamic IPv6 prefix.
Prefix Prefix and its length. If no prefix is obtained, this field displays
Not-available
.
Preferred lifetime 90
sec
Preferred lifetime in seconds. For a static IPv6 prefix, this field is not displayed.
valid lifetime 120 sec Valid lifetime in seconds. For a static IPv6 prefix, this field is not displayed.
Related commands
ipv6 dhcp client pd
ipv6 prefix
display ipv6 rawip
Use display ipv6 rawip to display brief information about IPv6 RawIP connections.
Syntax
display ipv6 rawip [ slot slot-number ]
Views
Any view
Predefined user roles
network-admin
network-operator
Parameters
slot slot-number: Specifies an IRF member device by its member ID. If you do not specify a member
device, this command displays brief information about IPv6 RawIP connections for all member
devices.
Examples
# Display brief information about IPv6 RawIP connections.
<Sysname> display ipv6 rawip
Local Addr Foreign Addr Protocol Slot PCB
2001:2002:2003:2 3001:3002:3003:3 58 1 0x0000000000000009
004:2005:2006:20 004:3005:3006:30
07:2008 07:3008
2002::100 2002::138 58 2 0x0000000000000008
:: :: 58 5 0x0000000000000002
Table 51 Command output
Field Description
Local Addr Local IPv6 address.
Foreign Addr Peer IPv6 address.
Protocol Protocol number.
PCB PCB index.

Table of Contents

Other manuals for HPE FlexFabric 5950 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HPE FlexFabric 5950 Series and is the answer not in the manual?

HPE FlexFabric 5950 Series Specifications

General IconGeneral
BrandHPE
ModelFlexFabric 5950 Series
CategorySwitch
LanguageEnglish

Related product manuals