327
Default
The aging time is 30 seconds.
Views
System view
Predefined user roles
network-admin
Parameters
aging-time: Sets the aging time in the range of 10 to 300 seconds.
Examples
# Set the aging time to 20 seconds for IPv6 fast forwarding entries.
<Sysname> system-view
[Sysname] ipv6 fast-forwarding aging-time 20
Related commands
display ipv6 fast-forwarding aging-time
ipv6 fast-forwarding load-sharing
Use ipv6 fast-forwarding load-sharing to enable IPv6 fast forwarding load sharing.
Use undo ipv6 fast-forwarding load-sharing to disable IPv6 fast forwarding load sharing.
Syntax
ipv6 fast-forwarding load-sharing
undo ipv6 fast-forwarding load-sharing
Default
IPv6 fast forwarding load sharing is enabled.
Views
System view
Predefined user roles
network-admin
Usage guidelines
IPv6 fast forwarding load sharing enables the device to load share packets of the same flow. This
feature identifies a data flow by using the five-tuple (source IP, source port, destination IP, destination
port, and protocol).
If IPv6 fast forwarding load sharing is disabled, the device identifies a data flow by the five-tuple and
the input interface. No load sharing is implemented.
Examples
# Enable IPv6 fast forwarding load sharing.
<Sysname> system-Views
[Sysname] ipv6 fast-forwarding load-sharing
reset ipv6 fast-forwarding cache
Use reset ipv6 fast-forwarding cache to clear the IPv6 fast forwarding table.