Page #105 background imageLoading...
Page #105 background image
96
Field Description
[12345]
• 1—Clock source selected by the system (the current reference
source).
• 2—The stratum level of the clock source is less than or equal to 15.
• 3—The clock source has survived the clock selection algorithm.
• 4—The clock source is a candidate clock source.
• 5—The clock source was created by a configuration command.
Total sessions Total number of associations.
# Display detailed information about all IPv4 NTP associations.
<Sysname> display ntp-service sessions verbose
Clock source: 192.168.1.40
Session ID: 35888
Clock stratum: 2
Clock status: configured, master, sane, valid
Reference clock ID: 127.127.1.0
VPN instance: Not specified
Local mode: client, local poll interval: 6
Peer mode: server, peer poll interval: 6
Offset: 0.2862ms, roundtrip delay: 3.2653ms, dispersion: 4.5166ms
Root roundtrip delay: 0.0000ms, root dispersion: 10.910ms
Reachabilities:31, sync distance: 0.0194
Precision: 2^18, version: 3, source interface: Not specified
Reftime: d17cbba5.1473de1e Tue, May 17 2011 9:17:25.079
Orgtime: 00000000.00000000 Thu, Feb 7 2036 6:28:16.000
Rcvtime: d17cbbc0.b1959a30 Tue, May 17 2011 9:17:52.693
Xmttime: d17cbbc0.b1959a30 Tue, May 17 2011 9:17:52.693
Roundtrip delay samples: 0.007 0.010 0.006 0.011 0.010 0.005 0.007 0.003
Offset samples: 5629.55 3913.76 5247.27 6526.92 31.99 148.72 38.27 0.29
Filter order: 7 5 2 6 0 4 1 3
Total sessions: 1
Table 18 Command output
Field Description
Clock source
IP address of the NTP server. If this field displays
0.0.0.0
, the IP
address of the NTP server has not been resolved successfully.
Clock stratum
Stratum level of the NTP server, which determines the clock
accuracy. The value is in the range of 1 to 16. A lower stratum
level represents greater clock accuracy. A stratum 16 clock is not
synchronized and cannot be used as a reference clock.

Table of Contents

Other manuals for HPE FlexNetwork 5130 HI SERIES