138
network-operator
Parameters
pse-id: Specifies a PSE by its ID. If you do not specify a PSE, this command displays detailed PSE
information about all PSEs.
Examples
# Display detailed PSE information.
<Sysname> display poe pse
PSE ID : 4
Slot No. : 1
SSlot No. : 0
PSE Model : LSP6POEB
PSE Status : Enabled
Power Priority : Low
Current Power : 0.0 W
Average Power : 0.0 W
Peak Power : 0.0 W
Max Power : 180.0 W
Remaining Guaranteed Power : 180.0 W
PSE CPLD Version : -
PSE Software Version : 140
PSE Hardware Version : 57633
Legacy PD Detection : Disabled
Power Utilization Threshold : 80
PD Power Policy : Disabled
PD Disconnect-Detection Mode : DC
Table 27 Command output
Field Description
PSE ID ID of the PSE.
Slot No. Slot number of the PSE.
SSlot No. Sublsot number of the PSE.
PSE Status
PoE status of the PSE:
• Enabled.
• Disabled.
Power Priority Power priority of the PSE.
Current Power Current power of the PSE.
Average Power Average power of the PSE.
Peak Power Peak power of the PSE.
Max Power Maximum power of the PSE.
Remaining Guaranteed Power
Remaining guaranteed power of the PSE = Maximum guaranteed
power of the PSE – Total maximum power of all critical PIs of the PSE.
PSE CPLD Version PSE CPLD version number.