Parameters
Keyword and Value Description Default Value
-i RAID group ID The RAID group ID. The
value ranges from 0 to 31.
None.
-n RAID group name The new name of the RAID
group. The name contains 1
to 32 characters, including
numbers, letters,
underscores, and hyphens.
The first character cannot be
a hyphen. The name of a
RAID group is case sensitive,
and must be unique.
None.
Modes
Normal mode.
Level
Super administrator level and administrator level.
Usage Guidelines
The command chgrg is used to change the name of a RAID group.
Example
Change the name of RAID group 1 to asd.
OceanStor: admin> chgrg -i 1 -n asd
6.1.4 showrg
Function
The command showrg is used to query the information about a RAID group.
Format
showrg [ -i RAID group ID ]
OceanStor S2600 Storage System
Command Reference 6 Service Management Commands
Issue 07 (2010-05-20) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
6-5