Keyword and Value Description Default Value
-i Link ID The link ID, the value ranges
from 0 to 255.
You can query the
information by running the
showlinkinfo command.
None.
Modes
Normal mode.
Level
Super administrator level, administrator level and guest level.
Usage Guidelines
None.
Example
Collect statistics information of the link with ID 0.
OceanStor: admin> statlink -i 0
=========================================
Link Statistic
-----------------------------------------
Link ID | 0
Read IO Number(Bytes) | 0
Write IO Number(Bytes) | 1
Read IO Total(Bytes) | 0
Write IO Total(Bytes) | 0
Current Bandwidth(MB/S) | 0
Max Bandwidth(MB/S) | 0
Current IOPS(IO/S) | 0
Max IOPS(IO/S) | 0
Max Delay(S) | 0
Average Delay(S) | 1
=========================================
System Response
None.
9.6.6 testlink
Function
The command testlink is used to test the statistics time of the link.
OceanStor S2600 Storage System
Command Reference 9 Value-Added Service Management Commands
Issue 07 (2010-05-20) Huawei Proprietary and Confidential