OceanStor: admin> showexplunnum -i 23
The number of this expanded LUN is 6
System Response
None.
9.4 Initiator and target (controller) Configuration
Commands
Initiator and target (controller) configuration commands are used to modify the information of
the initiator and target (controller).
9.4.1 addtgt
9.4.2 showtgt
9.4.3 connecttgt
9.4.4 chgtgt
9.4.5 disconnecttgt
9.4.6 chgiscsiininame
9.4.7 showiscsiname
9.4.8 deletetgtinfo
9.4.9 chgini
9.4.1 addtgt
Function
The command addtgt is used to add a related target (controller) to the initiator.
Format
addtgt -c controller ID -p port ID -ip IP address [-port TCP/IP port] [-m recovery mode] [-
chap yes or no] [-user user -pwd password]
Parameters
Keyword and Value
Description Default Value
-c controller ID
The controller ID. The value is A or B, and it is case
insensitive.
None.