Function
The command chgdisklight is used to set the status of the running indicator on a disk.
Format
chgdisklight -o operate code -s subrack id -sl slot id
Parameters
Keyword and Value Description Default Value
-o operate code The operation code. The
value can be 0 or 1, and is
described as follows:
l 0: The indicator is off.
l 1: The indicator is on.
None.
-s subrack id The enclosure ID. The value
ranges from 0 to 7.
None.
-sl slot id The slot ID of a disk. The
value ranges from 0 to 11.
None.
Modes
Normal mode.
Level
Super administrator level and administrator level.
Usage Guidelines
The command chgdisklight is used to set the status of the running indicator on a disk.
Example
Set the status of the running indicator on the disk in slot 4, enclosure 0 to be on.
OceanStor: admin> chgdisklight -o 1 -s 0 -sl 4
5.3 Controller Management Commands