4.2 Controller Configuration Commands
The controller configuration commands are used to set the status of the controller to offline, and
to query the information about the controller.
4.2.1 offline
4.2.2 showctrlinfo
4.2.1 offline
Function
The command offline is used to disable the services of the controller.
Format
offline -c controller ID
Parameters
Keyword and Value
Description Default Value
-c controller ID The controller ID. The value
is A or B, and is case
insensitive.
None.
Modes
Normal mode.
Level
Super administrator level and administrator level.
Usage Guidelines
When using this command, note the following items:
l For a storage system configured with two controllers, the command is used when the system
works properly.
l For a storage system configured with one controller, the command cannot be used.
Example
Disable the services of controller A.
OceanStor: admin> offline -c a
4 System Management Commands
OceanStor S2600 Storage System
Command Reference
4-8 Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Issue 07 (2010-05-20)