Example
Change the system time to 2008-12-17/11:05:00.
OceanStor: admin> chgsystime -t 2008-12-17/11:05:00
4.10 CHAP Setting Command
CHAP setting command is used to create, change, delete, and query CHAP user.
4.10.1 chap
4.10.1 chap
Function
The command chap is used to set CHAP-related functions for iSCSI host ports.
Format
chap { -adduser -user username -password password |-adduser -initiator initiator name -
user username |-chgpassword -user username -password password |-showuser [ -initiator
initiator name ] |-deluser [ -initiator initiator name] -user username1...usernameN | -
showinitiator [ -user username | -free ] |-chgchapuser -initiator initiator name1...initiator
nameN -status { START | STOP } |-addinitiator -initiator initiator name1 ...initiator
nameN |-delinitiator -initiator initiator name1 ...initiator nameN }
Parameters
Keyword and Value
Description Default Value
-adduser -user username -
password password
The command provides the
functions of adding a CHAP
user and setting the
password.
l -user username:
CHAP user name. The
name contains 4 to 25
characters, including
numbers, letters,
underscores, and hyphens.
The first character must be
a letter.
l -password password:
The password. It contains
12 to 16 characters.
None.