EasyManua.ls Logo

Huawei OceanStor S2600 - Replacing a Disk Module

Huawei OceanStor S2600
274 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Usage Guidelines
When using this command, note the following items:
l The command staterr -c controller ID -f is used to collect statistics on error codes of the
FC host ports on a specified controller.
l The command staterr -c controller ID -i is used to collect statistics on error codes of the
iSCSI host ports on a specified controller.
l The command staterr -c controller ID -c is used to collect statistics on error codes of the
mini SAS host ports on a specified controller.
Example
Collect statistics on error codes of the FC host ports on controller A.
OceanStor: admin> staterr -c a -f
Controller Port ID Link Status LSGENum BRCENum LSYNum LFENum
StartTime
A 00 Connected 1 765 255 1
2009-08-25 08:43:12
A 01 Connected 1 765 255 1
2009-08-25 08:43:12
A 02 Connected 1 765 255 1
2009-08-25 08:43:12
A 03 Connected 5 771 255 1
2009-08-25 08:43:12
4.5.6 cleanerr
Function
The command cleanerr is used to clear the error codes of the FC host ports and restart the
statistics of error codes.
Format
cleanerr [ -c controller ID ]
Parameters
Keyword and Value
Description Default Value
-c controller ID The controller ID. The value
is A or B, and is case
insensitive.
None.
Modes
Normal mode.
OceanStor S2600 Storage System
Command Reference 4 System Management Commands
Issue 07 (2010-05-20) Huawei Proprietary and Confidential