5.13.2 chgfps
Function
The command chgfps is used to change the rates of FC host ports.
Format
chgfps -c controller ID -i port ID -s speed
Parameters
Keyword and Value Description Default Value
-c controller ID The controller ID. The value
is A or B, and is case
insensitive.
None.
-i port ID The ID of an FC port. The ID
value ranges from 0 to 3.
l S2600F: Each host port
module is configured with
four FC host ports. From
left to right, the host ports
are numbered 0, 1, 2, and
3 in sequence.
l S2600C: Each host port
module is configured with
two FC host ports and two
iSCSI host ports. From left
to right, the FC host ports
are numbered 0 and 1 in
sequence.
None.
-s speed The rate of an FC host port.
The value can be 0, 1, 2, or 4.
l 0: Auto-adaptation.
l 1: The rate of 1 Gbit/s.
l 2: The rate of 2 Gbit/s.
l 4: The rate of 4 Gbit/s.
None.
Modes
Normal mode.
Level
Super administrator level and administrator level.
5 Device Management Commands
OceanStor S2600 Storage System
Command Reference
5-26 Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.