GAPS - User Guide
System Characteristics: This datagram gathers the identification elements of the system.
Description Format Unit Observation
Header
Synchronization byte '$'
Total Size byte 16
Datagram ID byte $81
Datagram release number byte $01
Parameters
Demodulation frequency float Herz
Maximum phase error float rad
Maximum phase jumps short
Checksum ushort
MU-GAPS-AN-005-H - November 2019 219