Global
P0
P1 P2 P3 P4 P5 P6
119
switched. However, the program changes for each timbre
will be affected by the setting of the Enable Program
Change parameter (Combination P3: 31a).
When you switch combinations, a program change message
will be transmitted on the global MIDI channel, and also
transmitted simultaneously on the channel of timbres whose
Status (Combination P0: 01f) is set to EXT or EX2.
In Sequencer mode, incoming program change messages on
a channel that corresponds to a track whose Status
(Sequencer P2: 21a) is set to INT or BTH will switch pro-
grams on that track. When you select a song or playback
sequencer data, program changes will be transmitted on the
channels of tracks whose Status is set to BTH, EXT, or
EX2.
Unchecked: Program changes will not be transmitted or
received.
Enable Bank Change
Checked: The Bank Select control change message will be
transmitted together with program change messages. This is
valid when Enable Program Change is checked.
Unchecked: Bank Select messages will not be transmitted or
received.
When recording on the internal sequencer, bank select
messages will be recorded regardless of this setting.
However for playback, this setting will apply.
Enable Combination Change
Checked: When in Combination P0: Play, an incoming pro-
gram change message on the global MIDI channel set by
MIDI Channel (11a) will switch combinations. This is
valid when Enable Program Change is checked. An
incoming program change on a channel other than the glo-
bal MIDI channel will switch the program of any timbre that
matches that MIDI channel.
Unchecked: An incoming program change message on the
global MIDI channel will switch the program of any timbre
whose MIDI Channel (Combination P2: 21a) matches the
global MIDI channel. The combination will not be switched.
The program changes for each timbre will be affected by the
setting of the Enable Program Change parameter (Combi-
nation P3: 31a).
Enable After Touch
Checked: MIDI after touch messages will be transmitted
and received.
Unchecked: MIDI after touch messages will neither be
transmitted nor received.
When recording sounds that do not require the use of after
touch, you can uncheck this parameter to save memory.
This setting has no effect when you use the internal
sequencer to playback sequence data that was recorded with
after touch data; i.e., after touch will be transmitted via MIDI.
The TRITONs keyboard transmits only channel after touch;
it does not transmit polyphonic after touch. However, since
the TRITON does support polyphonic after touch as an
Alternate Modulation Source (AMS), it can receive poly-
phonic after touch to control individual notes.
Enable Control Change
Checked: Control change messages will be transmitted and
received.
Unchecked: Control change messages will neither be trans-
mitted nor received.
This setting has no effect when you use the internal
sequencer to playback sequence data that was recorded with
control change data; i.e., control changes will be transmitted
via MIDI.
Enable Exclusive
Checked: System exclusive data will be transmitted and
received. Check this setting when you wish to use a con-
nected computer etc. to edit the TRITON, or vice versa.
Unchecked: System exclusive data will neither be transmit-
ted nor received. Normally you will leave this unchecked.
However, system exclusive data will be transmitted and
received while the page menu commands (Dump Pro-
gram”–”Dump All) of this page are displayed.
11: Page Menu Command
11A: Dump Program
11B: Dump Combination
11C: Dump Drum Kit
11D: Dump Arpeggio Pattern
11E: Dump Global Setting
11F: Dump Sequencer
11G: Dump All
These commands allow the TRITONs data to be transmitted
to another connected TRITON, MIDI data lter, or computer
in the form of system exclusive data.
Select the desired command (refer to the following table),
and a dialog box will appear.
If you selected a command other than Dump All (11G),
select the bank or timbre etc. of the data to be dumped. Then
press the OK button.
Transmission
Do not touch the TRITONs switches or turn off the
power while data is being transmitted.
Data dump transmission procedure
1 Connect the TRITON to the device that will receive the
data dump.
If you are using a computer that is able to receive MIDI
exclusive messages, connect the serial port of the com-
puter to the TO HOST connector of the TRITON.
Dump Program Programs of all banks, programs of the
specified bank, one program
Dump Combination Combinations of all banks, combinations of
the specified bank, one combination
Dump Drum Kit All drum kits, One drum kit
Dump Arpeggio Pattern All arpeggio patterns, One arpeggio pattern
Dump Global Global settings (except for the Drum Kits
and User Arpeggio Patterns of Global
mode)
Dump Sequencer All sequences
Dump All All banks of programs + combinations +
drum kits + arpeggio patterns + global set-
tings + sequences
01A
11A
11B
11C
11D
11E
11F
11G

Table of Contents

Other manuals for Korg TRITON proX

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Korg TRITON proX and is the answer not in the manual?

Korg TRITON proX Specifications

General IconGeneral
BrandKorg
ModelTRITON proX
CategorySynthesizer
LanguageEnglish

Related product manuals