Page 102 Firmware Ver. 1.00.42/Software Ver. 1.0.2.6 LEIGHTRONIX, INC.
2010-07-09
FIELD DESCRIPTION
Comment Allows up to 31 characters to be typed. If the event is locked, the
event “Time” can be modified. This is the scheduled “On-Air“ time of
the event.
Event Start
Command
Choose from the following commands: “Play,” “Stop,” “Rewind,” and
“Record.” It will nearly always be “Play.”
Setup,
Preroll,
Length, and
Reset time
Fixed in the device and library item properties. Reset time is only used
if the end command is “Rewind.”
Event End
Command
Choose from the following commands: “Play,” “Stop,” “Rewind,” and
“Record.” It will usually be “Rewind” or “Stop.” For DVD, check your
interface manual and switches to determine the actions performed by
the “Rewind” and “Stop” commands. By default, “Rewind” does a DVD
full stop (back to beginning), and “Stop” stops the DVD at the current
location.
Fallback
input field
Enter the input to be taken to the output at the end of the event.