NET Series
Controller Installation and Configuration
Page 30 Firmware Ver. 1.00.42/Software Ver. 1.0.2.6 LEIGHTRONIX, INC.
2010-07-09
CONFIGURING SWITCHER
NET-EC only: use to set the external switcher type and the number of inputs, outputs,
and level that will be switched (see Table 5, Setting Switcher Type from Front Panel).
NOTES:
The NET-EC supports router sizes up to 32 inputs by 32 outputs by 8
levels. Check your routing switcher manual for the number of levels that
are present in your router.
The switcher configuration may also be set from WinNET (see
“Configuring Controller Properties,” on page 67).
Table 5, Setting Switcher Type from Front Panel
SWITCHER CONFIGURATION STEPS CORRESPONDING SCREEN DISPLAYS
1. From the “MAIN MENU” screen, press “↑” or
“↓” to proceed to “Setup.”
2. Press “→” to select “Setup.”
3. Press “↑” or “↓” to proceed to “Switcher
Configuration.”
4. Press “→” to select “Switcher Configuration.”
5. Press “→” or “←” to position the underscore
under the editable fields and press “↑” or “↓”
to edit the values.
6. Press “→” to enter next screen.
7. Either press “→” again to save your changes
or “←” to abort changes.
Press ~ to save
Switcher configuration.
SETUP MENU Use `/ˆ
Switcher Configuration
~
MAIN MENU Use `/ˆ
Setup
~
SW:PESA
In:16 Out:16 Lvls:3