3. OVER LOAD PROTECTION
IOLT: IOLT(inverter Overload Trip) protection is activated at 110% of the inverter rated current for 1
minute and greater.
OLT : Inverter shuts off its output when inverter output current exceeds its overload trip level for
overload trip time. OLT is selected when FU1-66 is set to “Yes” and activated at 120% of FU1-67
[Motor rated current] for 60 sec set in FU1-68.
4. OVER SPEED PROTECTION
Not Provided With Overspeed Protection.
5. FIELD WIRING TERMINAL
1) Use copper wires only with 600V, 75 ratings
2) Tightening torque of power terminal blocks
Screw Torque
1
Wire
2
mm²
AWG or kcmil
Inverter Capacity
[kW]
Terminal
Screw
Size
Kgf·cm lb-in
R,S,T U,V,W R,S,T U,V,W
5.5 M4
7.1 ~ 12.2 6.2~10.6
5.5 5.5 10 10
7.5 M5 8 8 8 8
11 M5
24.5 ~ 31.8 21.2~27.6
14 14 6 6
15 M6 22 22 4 4
18.5 M6
30.6 ~ 38.2 26.6~33.2
38 38 2 2
22 M8 38 38 2 2
200V
Class
30 M8
61.2 ~ 91.8 53.1~79.7
60 60 1/0 1/0
5.5 M4 3.5 3.5 12 12
7.5 M4 3.5 3.5 12 12
11 M4
7.1 ~ 12.2 6.2~10.6
5.5 5.5 10 10
15 M6 8 8 8 8
18.5 M6
30.6~38.2 26.6~33.2
14 14 6 6
22 M8 22 22 4 4
30 M8
61.2~91.8 53.1~79.7
22 22 4 4
37 M8 38 38 2 2
45 M8 38 38 2 2
55 M8
67.3~87.5 58.4~75.9
38 38 2 2
75 M10 60 60 1/0 1/0
90 M10
89.7~122.0 77.9~105.9
60 60 1/0 1/0
110 M12 100 100 4/0 4/0
132 M12 100 100 4/0 4/0
160 M12 150 150 300 300
220 M12
182.4~215.0 158.3~186.6
200 200 400 400
280 M12 250 250 500 500
315 M12 325 325 700 700
375 M12
2×200 2×200 2×400 2×400
400V
Class
450 M12
182.4~215.0 158.3~186.6
2×250 2×250 2×500 2×500
1
Apply the rated torque to terminal screws. Loose screws can cause of short circuit or malfunction. Tightening the screws too
much can damage the terminals and cause a short circuit or malfunction.
3) For 7.5~11kW 240V type inverters, Input and motor output terminal blocks are intended only for
use with ring type connectors.