MFD(b,m) ' m=1 for ramp output to match cam input units.
MC
MCW(1,0) ' Required to select table.
G
RETURN
CAUTION: When writing a cam table to EEPROM, structure the program so
that the cam table is not frequently rewritten or written from a loop. Repeated
erasing and rewriting can burn bits and corrupt data. For details and sample
code, refer to Electronic Camming Notes and Best Practices on page 159.
Camming - Fixed Cam with Input Variables