5.4.5.12 Overriding Environmental Sensor Configuration
Overriding a Device Configuration
An AP8132 sensor module is a USB environmental sensor extension to an AP8132 model access point. It provides a variety of
sensing mechanisms, allowing the monitoring and reporting of the AP8132's radio coverage area. The output of the sensor's
detection mechanisms are viewable using the Environmental Sensor screen.
To set an environmental sensor configuration for an AP8132 model access point:
1. Select the Configuration tab from the Web UI.
2. Select Devices.
3. Select Device Overrides from the options on left-hand side of the UI.
4. Select Environmental Sensor.
Figure 5-255 Profile - Environmental Sensor screen
5. Override or set the following Light Sensor settings for the AP8132’s sensor module:.
NOTE: This feature is available on the AP8132 model only.
Enable Light Sensor Select this option to enable the light sensor on the module. This setting is enabled by
default.
Polling Time to
Determine if Light is On/
Off
Define an interval in Seconds (2 - 201) or Minutes (1 - 4) for the sensor module to poll its
environment to assess light intensity to determine whether lighting is on or off. The
default polling interval is 11 seconds. Light intensity is used to determine whether the
access point’s deployment location is currently populated with clients.
Shutdown WLAN Radio
at Low Limit of Light
Threshold
Select this option to power off the AP8132’s radio’s if the light intensity falls below the set
threshold. If enabled, select All (both AP8132 radios), radio-1 or radio-2.