5 - 192 WiNG 5.6 Access Point System Reference Guide
6. Set the appropriate Root Path Monitor Interval value. This setting configures the frequency at which the path to the root
mesh point is monitored.
7. Set the Additional Port value for RADIUS Dynamic Authorization field. Set this value to 1700 to enable a CISCO
Identity Services Engine (ISE) Authentication, Authorization and Accounting (AAA) server, when deployed in the network,
to dynamically authenticate a client.
When a client requests access to the network, the CISCO ISE RADIUS server presents the client with a URL where the
device’s compliance to the networks security such as validity of anti-virus or anti-spyware software is checked for the
validity of their definition files (this checking is called posture). If the client device complies, then it is allowed access to
the network.
8. Select OK to save the changes made to the profile’s Advanced Miscellaneous configuration. Select Reset to revert to the
last saved configuration.
5.2.14 Environmental Sensor Configuration
System Profile Configuration
An AP8132 sensor module is a USB environmental sensor extension to an AP8132 model access point. It provides a variety of
sensing mechanisms, allowing the monitoring and reporting of the AP8132's radio coverage area. The output of the sensor's
detection mechanisms are viewable using the Environmental Sensor screen.
To set an environmental sensor configuration for an AP8132 model access point:
1. Select the Configuration tab from the Web UI.
2. Select Devices.
3. Select System Profile from the options on left-hand side of the UI.
4. Select Environmental Sensor.
Figure 5-127 Profile - Environmental Sensor screen
NOTE: This feature is available on the AP8132 model only.