Spitfire – Maintenance Manual
27
AP-74096, Rev. 1.0, 09/06/05
2.3.3. Position and function of the heating elements
Heater element Temperature Function
Pre-heater (Heater A) 20 – 50°C
Open the pores to make the media more receptive
for Spitfire Mild Solvent Ink.
Fixer (Heater B) 20 – 40°C
To establish optimum fixation onto the media
(coated and uncoated).
Optimizes the dot gain control.
Post-Fixer (Heater C) 20 – 70°C
The post-fixer finalizes the fixation process and
helps to make the prints touch-dry.
Dryer (Heater D) 20 – 50°C
The dryer completes the drying for compatibility
with the take-up in combination with higher output
speeds.
Stickiness of printed banner materials is improved.
There have been a number of requests from the field, asking the heaters to be on by default for a few user
settings. This has now been implemented as follows:
1) For user 1 and user 8 default settings are as follows:
a. Pre heater A: 50°C
b. Fixer B: 40°C
c. Post Fixer C: 50°C
d. Dryer D: 50°C
2) For users 2 Î 7, by default the heaters are still OFF.
Notes :
Please note some RIP software do not allow selection of the user from software
side. In some cases, however, they do automatically activate user 8.