160 5 HARD START AND NO START DIAGNOSTICS
• If ICP voltage is out of specification at engine
crank only, do Test 14 – “Low ICP System
Pressure” (page 186).
• If ICP voltage is in specification at KOEO
and builds to cranking voltage during engine
crank, continue to “Monitoring B CP usin g V C
Gasket Breakout Harness” test
EGES-270-1
Read all safety instructions in the "Safety Information" section of this manual before doing any proced ures.
Follow all warnings, cautions, and notes.
©August 2008 Navistar, Inc.