178 5 HARD START AND NO START DIAGNOSTICS
Possible Causes
Low battery voltage
Failed batteries
High-resistance at battery cable connections
Wiring to the IDM
Low or no battery voltage to the IDM main power
relay
High-resistance or an open power feed circuit to
the IDM or IDM main power relay.
The I D M pow e r circuit fuse in ba tt ery box may be
open.
IDM main power relay may have failed.
•V
IGN
circuit problem
Failed IDM
EGES-270-1