B - 6 Barge-In
Issue 6 Electra Elite
1. Lift the handset or press
P
, and wait for internal dial tone.
2. Press
T
, then press
R
.
3. Press the CO/PBX line key to be interrupted.
4. Interrupt is enabled.
SERVICE
CONDITIONS
Data Assignment:
Multiline Terminals can be used to interrupt the privacy of
conversations on outside lines.
Use Memory Block 1-1-76 (Barge-In Alert Tone Assignment) to allow
(default: YS) or deny (NO) an alert tone during Barge-In.
Use Memory Block 1-8-08[Class of Service (Station) Feature
Selection 2] Page 1 LK4 to Allow (LED On) or Deny (default: LED Off)
Barge-In Originate.
Use Memory Block 1-8-08 [Class of Service (Station) Feature
Selection 2] Page 1 LK5 to Allow (default: LED On) or Deny (LED Off)
Barge-In Receive.
Each Barge-In in progress uses a conference circuit.
Restrictions:
Barge-In is not allowed for internal calls.
Barge-In is not allowed until the Elapsed Call Time starts.
Add-On Conference calls cannot be interrupted.
The Barge-In feature is not permitted when 16 Add-On Conferences
are in progress.
The Barge-In feature does not override conversation on a Private
Line.
A Single Line Telephone user cannot activate Barge-In; however, the
conversation on a Single Line Telephone can be interrupted.
The Barge-In feature cannot be used on outside lines for another
tenant unless the lines are assigned to both tenants.
Data Line Security prevents a station from being barged in on, even
when Barge-In is allowed in Class of Service.
Barge-In is not allowed on outside lines on Hold.
To Barge-in using an outside line key: