Features and Specifications Manual C - 67
Class of Service
C-17
FEATURE
DESCRIPTION
Class of Service assigns and controls access to features. Various Class of
Service combinations can be programmed. Stations are then assigned
according to the features they can access.
SYSTEM
AVAILABILITY
Terminal Type:
All Multiline Terminals
Required Components:
None
OPERATING
PROCEDURES
SERVICE
CONDITIONS
Data Assignment:
Use Memory Block 1-8-07 [Class of Service (Attendant) Feature
Selection 1] to assign Class of Service Attendant Features.
Use Memory Block 1-8-08 [Class of Service (Station) Feature Selection
2] to assign Station Features.
Use Memory Block 4-17 (Station to Class of Service Feature
Assignment) to assign each station to one class for both Class of
Service Assignments.
At default, Memory Block 1-8-07 [Class of Service (Attendant) Feature
Selection 1] Station Class 00 is set to Allow (LED On) all features
(except System-Wide Reset) and Station Classes 01~15 are set to Deny
(LED Off) all features.
At default for Attendant Features, Stations 100 and 101 are set for Class
00 and all others stations are assigned Class 15 using Memory Block
4-17 (Station to Class of Service Feature Assignment).
At default, Memory Block 1-8-08 [Class of Service (Station) Feature
Selection 2] Station Class 00 is set to Allow (LED On) most features.
Station Classes 01~15 are set to Deny (LED Off) all features.
None