Features and Specifications Manual R- 13
Restriction (Outgoing)
R-6
FEATURE
DESCRIPTION
Restriction (Outgoing) prohibits station users from originating outside calls per
station/per trunk. At stations where Outgoing Restriction is assigned, a user
can answer an incoming call, place and receive an internal call, or pick up a
held line on a specified trunk. The number of digits dialed on outgoing calls
may also be restricted per station.
SYSTEM
AVAILABILITY
Terminal Type:
All Multiline Terminals
Required Components:
None
OPERATING
PROCEDURES
SERVICE
CONDITIONS
Data Assignment:
Use Memory Block 4-19 (Trunk Outgoing Restriction) to specify
Outgoing Restriction per CO/PBX line.
General:
The default program assigns no restrictions to any station.
When you press the Recall key or any key on the dial pad (while
receiving dial tone), the CO/PBX line is dropped and reorder tone is sent
to the station user.
Restricted outside lines cannot be seized by using a Trunk Access
Code.
RELATED
FEATURES LIST
Depends on System Programming.
Feature
Number
Feature Name
C-19 Code Restriction