Features and Specifications Manual N - 5
Night Call Pickup
N-2
FEATURE
DESCRIPTION
Night Call Pickup functions when the system is in Night Mode and an incoming
call rings. When the Night Chime is ringing, a station user can dial the Night
Call Pickup Access Code or press a Feature Access key programmed for
Night Call Pickup to answer incoming calls.
SYSTEM
AVAILABILITY
Terminal Type:
All Multiline Terminals
Required Components:
ECR-U10 ETU
OPERATING
PROCEDURES
1. Lift the handset, and wait for internal dial tone.
2. Dial the Night Call Pickup Access Code
FI
(default).
- OR -
Press the Feature Access key programmed for Night Call Pickup.
3. Connection to incoming call is completed.
Note: Default Access Codes can be changed in System Programming during installation.
SERVICE
CONDITIONS
Data Assignment:
Use Memory Blocks 1-1-46~48 [Access Code (1-, 2-, or 3-Digit)
Assignment] to assign the Night Call Pickup Access Code (default: 69).
Use Memory Block 2-08 (ECR Relay to Tenant Assignment) to specify
Tenant assignment (LED On) to External Tone Relay 1, 2, 3, 4, or Night
Chime function for the ECR Relay. Default is unassigned.
Use Memory Block 7-1 (Card Interface Slot Assignment) to specify the
ECR-U10 ETU.
For a Night Mode incoming outside call (Night Chime Ringing):