C - 60 Call Pickup Group
Issue 6 Electra Elite
SERVICE
CONDITIONS
Data Assignment:
Use Memory Blocks 1-1-46 and 1-1-47 [Access Code (1- or 2-Digit)
Assignment] to assign the following other Call Pickups that do not
have an Access Code at default:
• Call Pickup CO/PBX by Tenant (1-digit)
• Call Pickup CO/PBX/Centrex by Tenant (2-digit)
• Call Pickup CO/PBX for other Tenants
• Internal/CO/PBX Transfer Call Pickup in Same Tenant
• Call Pickup CO/PBX in Same Tenant
• Call Pickup (Tie only) in Same Tenant
• Call Pickup (PBX only) in Same Tenant
• Call Pickup (CO only) in Same Tenant
Restrictions:
Voice announced internal calls cannot be picked up in the same
Tenant Group.
General:
Call Pickup Groups are created by assigning Tenant Groups. A
maximum of 48 Call Pickup Groups can be assigned.
All Call Pickup Access Codes are valid for both Day Mode and Night
Mode except the Night Call Pickup Access Code. The Night Call
Pickup Access Code is valid when a tenant is in Night Mode and the
Night Chime feature is programmed.
An incoming Tie/DID call is first treated as an internal call. After
timeout (default: No Timeout), the incoming call is treated as an
incoming CO/PBX outside call.
When incoming calls terminate on two or more stations
simultaneously, the internal call with the lowest station number is
answered first.
To Call Pickup a Secondary Incoming Extension, a user must dial the
applicable Access Code to pick up the original call.