C - 72 Clock/Calendar Display
Issue 6 Electra Elite
12. Use the dial pad to enter the last two digits of the year.
13. Press
T
.
SERVICE
CONDITIONS
Data Assignment:
Use Memory Block 1-8-04 [Time Display (12h/24h) Selection] to
assign the system-wide clock to display 12 hours (default:12:00 to
11:59 AM/PM) or 24 hours (00:00 to 23:59).
Use Memory Block 1-8-48 (Automatic Daylight Saving Time
Selection) to allow (default) or deny the system clock to be adjusted 1
hour for the Daylight Savings Time Change. System Software
S6000 or higher is required.
Restrictions:
The Clock/Calender Display can be programmed only from station
port 01 or 02.
When the Electra Elite main processor is off during the Automatic
Daylight Saving Time adjustment, the clock will not automatically
adjust when system power is returned.
General:
The Clock Calender Display is protected by memory back-up power.
The system automatically adjusts the clock 1 hour ahead on the First
Sunday in April or sets the clock back 1 hour on the last Sunday in
October when allowed in Memory Block 1-8-48 (Automatic Daylight
Saving Time Selection). System Software S6000 or higher is
required.