D - 42 Distinctive Ringing
Issue 6 Electra Elite
Use Memory Block 3-07 (CO/PBX Ringing Variation Selection) to
specify a L (low), M (medium), or H (high) ringing tone (default: M)
for incoming outside line calls only for each CO/PBX line assigned in
Memory Block 1-1-28 (Distinctive Ringing by Telephone or CO
Selection).
Use Memory Block 4-91 (Telephone Ringing Variation Selection) to
specify a L (low), M (medium), or H (high) ringing tone (default: M)
for incoming outside line calls only for each telephone assigned in
Memory Block 1-1-28 (Distinctive Ringing by Telephone or CO
selection).
Use Memory Block 1-1-13 (CO Transfer Ring Pattern Selection) to
select a Ring Pattern for CO transfers. Default is C.
Use Memory Block 1-1-14 (CO Transfer Ring Tone Selection) to
select a Ring tone for CO transfers. Default is A.
The transfer tone and pattern are used for the transferred calls
regardless of the tone and pattern initially used by the trunk.
Use Memory Block 1-2-20 (Intercom Ring Tone Selection) to select a
system-wide intercom tone for Multiline Terminals (default A).
Use Memory Block 4-55 (CO/PBX Telephone Ringing Pattern
Selection) to specify ringing pattern for each telephone.
System Software S5000 or higher is required.
Use Memory Block 4-57 (CO Line Ringing Pattern Priority Selection)
to specify priority for station or CO line ringing.
System Software S5000 or higher is required.
General:
Incoming outside and internal calls use flexible ringing tones and
patterns.
Distinctive ringing patterns are as follows:
Internal ring tone has a pattern of 1 sec. On/2 sec. Off (default).
Incoming CO/PBX outside calls are assigned synchronous ring.
The ringing pattern connected from the exchange to the CO/
PBX/Centrex lines is repeated at all stations assigned to ring,
except for Single Line Telephones connected to ADA(2)-W(BK)/
(SW) Unit or APR-U Unit.
When synchronous ringing is disabled, an incoming CO call can
be assigned to ring at one pattern and an incoming PBX/
Centrex call can ring at a different pattern.
Incoming TIE/DID outside calls provide a distinctive ring pattern
of 2 seconds ON/4 seconds OFF (system default).