L - 6 Least Cost Routing (LCR)
Issue 6 Electra Elite
Use Memory Block 7-3-01 [MIF (LCR) Assignment] to enable the
LCR function on the MIFM-U10 ETU with an installed KMM(1.0)U.
Trunk groups 2~32 are programmable in station class of service to
bypass LCR at stations assigned for LCR.
Local Call Override of LCR is available in LCR Programming.
The Priority Selection in the Route Advance Table is set using LCR
Programming.
Restrictions:
Route Advance Blocks assigned on a line key bypass LCR.
When the Electra Elite 48/192 system has KF registration, this
feature is not available.
Outgoing calls using DISA cannot access LCR.
General:
LCR is programmed using a Personal Computer and diskette through
the MIFM-U10 ETU. This is the PC programming connection.
All Trunk groups in the system (except 00) can be accessed using
LCR.
Trunk Group 1 Access Code (default: 9) activates LCR at stations
assigned for LCR.
LCR is based on the first six digits (Area Code and Office Code)
dialed.
When using Code Restriction with LCR, Code Restriction is applied
to the digits dialed by the system.
Extra Code Tables can be programmed to provide OCC Access
Codes and pauses for the distant-end system.
The maximum number of extra code digits is 32, including pauses
(each pause counts as one digit).
LCR provides up to eight different routes for each call.
When the station user seizes the most expensive trunk, alarm tone is
not provided.
When the interdigit time exceeds 10 seconds, the outgoing call, using
LCR, is disconnected.
When the station user places an outside call using LCR, Trunk
Queuing cannot be set.

Table of Contents