R - 2 Recall Key
Issue 6 Electra Elite
Use Memory Blocks 1-1-46 and 1-1-47 [Access Code (1- or 2-Digit)
Assignment] Function Number 027 to specify an access code
(default 6#) to also allow SLT Hookflash.
General:
The Recall key functions only on Loop Start or Ground Start Trunks.
A Drop key can be programmed on a Flexible Line key or One-Touch
key to be used for abandoning a call and retaining the same PBX/
Centrex line.
While receiving busy, error tone, or an internal call, press the Recall
key to provide a new internal dial tone.
When you press the Recall key at an LCR station during a
conversation with an outside party and a CO Trunk is assigned using
Memory Block 3-91 (Trunk Type Selection), the following occur:
• The current call is dropped.
• A new Least Cost Routing dial tone is heard.
• Station Message Detail Recording starts again.
• Code Restriction starts again.
When you press the Recall key during a conversation with an outside
party, a PBX Trunk is assigned using Memory Block 3-91 (Trunk Type
Selection), and Least Cost Routing Recall is assigned as Allow (LED
On) using Memory Block 1-8-08 [Class of Service (Station) Feature
Selection 2] Page 4 LK1, the following occur:
• The current call is held by a PBX trunk.
• A new PBX dial tone is heard.
• Station Message Detail Recording starts again.
• Code Restriction starts again.
When you press the Recall key during a conversation with an outside
party, a PBX Trunk is assigned using Memory Block 3-91 (Trunk Type
Selection), and Least Cost Routing Recall is assigned as Deny (LED
Off) using Memory Block 1-8-08 [Class of Service (Station) Feature
Selection 2] Page 4 LK1, the following occur:
• The current call is dropped.
• A new CO dial tone is heard.
• Station Message Detail Recording starts again.
• Code Restriction starts again.