S - 14 Single Line Telephone Access
Issue 6 Electra Elite
Lift the handset, and communicate.
1. Press the hookswitch momentarily, and wait for internal dial tone.
2. Dial the station number where call is to be transferred.
3. Hang up.
1. Lift the handset, and wait for internal dial tone.
2. Dial the Feature Access Code.
SERVICE
CONDITIONS
Data Assignment:
All Feature Access Codes can be used from a Single Line Telephone
when allowed by Station Class of Service and applicable
assignments.
Use Memory Block 1-3-01 (Bounce Protect Time Selection) to specify
the time (default: 300 ms) before a valid hookflash is detected from
an SLT.
Use Memory Block 1-3-02 (SLT Hookflash Signal Selection) to
specify Whether a line is held internally (default: HOLD) or a
hookflash (FLASH) is sent to an outside line when a Single Line
Telephone user performs a hookswitch.
Use Memory Block 1-3-03 (First Digit PBR Release Time Selection)
to specify the time (default: 10 seconds) that a PBR circuit is
connected before disconnecting when a DTMF SLT user goes off-
hook. When user dials a digit before the PBR is disconnected, PBR
interdigit time begins.
Use Memory Block 1-3-04 [Dial 1 (DP) Hookflash Selection] to
specify whether (default: YS) or not (NO) pressing 1 during an
intercom call or a CO/PBX call on a DP Single Line Telephone
provides a hookflash signal (default is YS).
To answer outside or internal calls:
To transfer an outside call or internal call with a call in progress:
To access feature: