S - 48 Station Message Detail Recording (SMDR)
Issue 6 Electra Elite
Use Memory Block 1-5-25 (SMDR Valid Call Time Assignment) to
specify the SMDR Valid Call Time (default: 040s) before SMDR
outputs a record. Incoming transfer or conference calls and outgoing
calls are not output through SMDR until the SMDR Valid Call Time
has elapsed.
Use Memory Block 1-5-26 (SMDR Incoming/Outgoing Print
Selection) to assign SMDR to output incoming calls (INC), outgoing
calls (default: OUT), or ALL Calls.
Use Memory Block 4-56 (SMDR Telephone Print Selection) to
specify whether (default YES) or not (NO) a call record is printed for
the specified station. System Software S5000 or higher and MIFM
Software Version 3.00 or higher are required.
Use Memory Block 7-1 (Card Interface Slot Assignment) to specify
the required MIFM-U10 ETU.
Use Memory Block 7-3-01 [MIF (LCR) Assignment] to specify LCR.
Use Memory Block 7-3-02 [MIF (SMDR) Assignment] to specify
SMDR.
Restrictions:
Call records are not provided for internal calls.
Caller ID name is not printed on SMDR.
When the system automatically switches the clock for daylight saving
time and a station is on a call, the duration of that call is invalid.
System Software S6000 or higher with Automatic Daylight
Saving Time Selection set to allow affects this.
General:
When the printer or other I/O device fails to operate, approximately
100 call records are saved in the MIFM-U10 ETU buffer. When the
buffer is full, the first call record is lost and the last call record is
stored.
Call record data provides the Start Time, Trunk Number, Trunk
Group, Type of Call, Station Number, Duration, Number Dialed, LCR,
Calling Station Number, and Transferred Station Number.
The maximum digits allowed for output of a telephone number is 24.
When Printer is assigned, and a printer is not connected to the
system, a PRINTER TROUBLE LCD indication and an audible alert
tone are provided at the first two Multiline Terminals connected to the
system (Stations 100 and 101). When an MIFM-U10 ETU is not
installed or disabled, no alarm indication is given.

Table of Contents