S - 54 Station Outgoing Lockout
Issue 6 Electra Elite
1. Go off-hook, and wait for internal dial tone.
2. Dial Password cancel Access Code from another station.
(default: not assigned).
3. Dial the station number.
4. Wait for confirmation tone, and hang up.
1. Go off-hook, and wait for internal dial tone.
2. Dial Password change Access Code (default: not assigned).
3. Dial current Password.
4. Enter new Password.
5. Hang up.
SERVICE
CONDITIONS
Data Assignment:
Use Memory Blocks 1-1-46~48 [Access Code (1-, 2-, or 3-Digit)
Assignment] Function number 038 to assign Access Code for Reset
Password from Attendant.
Use Memory Blocks 1-1-46~48 [Access Code (1-, 2-, or 3-Digit)
Assignment] Function number 037 to assign Access Code for
Change Password.
Use Memory Block 1-1-70 (Code Restriction Class Assignment when
Lockout is Set) to assign the Code Restriction Class (default: 15)
when a station user sets Station Outgoing Lockout or when the
Attendant sets Attendant Station Outgoing Lockout.
Use Memory Block 1-8-07 [Class of Service (Attendant) Feature
Selection 1] Page 2 LK4 to Allow (default: LED On) or Deny (LED Off)
Cancel Station lockout and default Password for another station by
Attendant Class of Service.
Use Memory Block 1-8-08 [Class of Service (Station) Feature
Selection 2] Page 2 LK8 to Allow (default: LED On) or Deny (LED Off)
Telephone (DISA) Password by Station Class of Service.
To cancel Telephone Password and Default Password using the
Attendant Position:
To change the Password: