Alarm
No.
Type
Re-
port
Name
Content of
Alarm
Cause Action Recovery
Alarm
Status
57 2 0 IP Colli-
sion error
Check the IP
Address colli-
sion (CPU,
VOIPDB, Pro-
gram 84-26-01
GW : 1 ~ 8).
Collision IP Ad-
dress in the net-
work.
Check the IP Ad-
dress in the net-
work.
Recover the
IP Address
collision.
WAR
59 2 0 Network-
ing port
limit ex-
ceeded
(V1.5
Added)
Total number of
ports exceeded
the limit of 168
ports in the net-
work.
New extension
or trunk ports
are added.
A new system is
added in Pro-
gram 10-27-01.
A new system is
connected to the
network.
EXIFU is con-
nected.
Reduce extensions
or trunks not to ex-
ceed 168 ports in
the network.
When the to-
tal number of
ports be-
comes 168 or
less, the error
is recoverd.
ERR
60 2 0 SIP Reg-
istration
Error No-
tification.
1. The regis-
tration of
the SIP
trunk to the
SIP server
failed.
2. The regis-
tration of
the SIP
trunk to the
SIP server
failed in the
authentica-
tion.
3. There is no
response
from the
SIP server
to the SIP
registration
request.
1. The setting of
the system da-
ta is wrong.
2. The setting of
the router is
wrong.
3. It is an error to
the link of
LAN.
4. Net side trou-
ble.
1. Confirm the
following sys-
tem data set-
ting -- Pro-
grams 10-12,
10-28, 10-29,
10-30, and
10-36.
2. Confirm the
setting of rout-
ers.
3. Confirm
whether ab-
normality oc-
curs on the net
side.
4. Confirm the
authentication
system data
setting.
5. Confirm wiring
and the sys-
tem data set-
ting. Please in-
quire on un-
certain points
of the maker.
The error is
recovered
when normal-
ly connecting
it.
ERR
REC
61 0 0 SIP ex-
tension
trouble in-
formation.
1. Failed reg-
istration of
the SIP ex-
tension ter-
minal.
2. The SIP ex-
tension ter-
minal was
not ac-
quired:
At Regist of
the SIP exten-
sion terminal
to SL1100.
When you
cannot ac-
quire the DSP
resource
when it sent.
1. The registered
port is used by
other exten-
sion.
2. The license is
insufficient.
3. DSP of
VoIPDB not
acquired.
1. Confirm wiring
and the sys-
tem data set-
ting.
2. Confirm
whether each
equipment
such as ac-
cess points
works normal-
ly.
ERR
REC
SL1100 ISSUE 6.0