EasyManua.ls Logo

Newtec MDM9000 - Environmental; Appendix - Alarm List

Default Icon
400 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Newtec Proprietary
Confidentiality: Unrestricted
R3.2_v1.0
8/387
Safety Regulations
MDM9000 Satellite Modem
3.1 Environmental
Operating the equipment in an environment other than that stated in the specifications also
invalidates the safety compliance.
Do not use the equipment in an environment in which the unit is exposed to:
Unpressurized altitudes higher than 2000 meters
Extreme temperatures outside the stated operating range operating
temperature range 0 to + 50°C
Excessive dust
Moist or humid atmosphere above 85% RH
Excessive vibration
Flammable gases
Corrosive or explosive atmospheres
Direct sunlight
Use a slightly damp cloth to clean the casing of the equipment. Do not use any
cleaning liquids containing alcohol, methylated spirit or ammonia, ...
3.2 Rack Mounting Instructions
Elevated Operating ambient - If installed in a closed or multi-unit rack assembly, the operating
ambient temperature of the rack environment may be greater than room ambient. Therefore,
consideration should be given to installing the equipment in an environment compatible with the
maximum ambient temperature (Tma) specified by the manufacturer. 50°C.
Reduced Air Flow - Installation of the equipment in a rack should be such that the amount of air
flow required for safe operation of the equipment is not compromized.
Mechanical Loading - Mounting of the equipment in the rack should be such that a hazardous
condition is not achieved due to uneven mechanical loading.
Circuit Overloading - Consideration should be given to the connection of the equipment to the
supply circuit and the effect that overloading of the circuits might have on overcurrent protection
and supply wiring. Appropriate consideration of equipment nameplate ratings should be used
when addressing this concern.
Reliable earthing - Reliable earthing of rack-mounted equipment should be maintained. Particular
attention should be given to supply connections other than direct connections to the branch
circuit (for example use of power strips).

Table of Contents

Related product manuals