EasyManua.ls Logo

Newtec MDM9000 - AUPC Logging

Default Icon
400 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Newtec Proprietary
Confidentiality: Unrestricted
R3.2_v1.0
222/387
Feature Descriptions
MDM9000 Satellite Modem
The following table describes the alarm states table:
Parameter
State
Description
Alarm States
Index 1
This is the ID of your demodulator.
AUPC Client
Calibration
Absent
This alarm indicates that the AUPC client subsystem
has not been calibrated.
AUPC Client
Calibration
violation
This alarm indicates that the AUPC client wants to
operate outside the calibrated range.
16.8.5.5 AUPC Logging
The logging files are useful during evaluation of the AUPC feature but they also become important
during debugging.
Logging files of the AUPC can always be viewed or downloaded from the Tasks Pane (Refer to the
following figure).
To be able to perform good logging it is mandatory that the date and the time of all the
devices in the system setup are correctly configured.
The following Log files are available.
Client Log
AUPC terminals Log
AUPC level log

Table of Contents

Related product manuals