7210 SAS-MXP, R6, R12, S, SX, T BASIC SYSTEM
CONFIGURATION GUIDE RELEASE 22.9.R1
Boot options
uplinkB-address 0
uplinkB-vlan 0
#System Settings:
wait 3
persist off
console-speed 115200
uplink-mode access-uplink
no console-disabled
secure-bof-password enable
Do you want to overwrite cf1:/bof.cfg with the new settings? (yes/no): y
Successfully saved the new settings in cf1:/bof.cfg
----------------------------
4.7 OOB Ethernet management port
The 7210 SAS platforms support the OOB Ethernet management port for management of the node. An
OOB Ethernet port can be used to download the TiMOS image file and the configuration file by creating a
BOF manually. The OOB management port allows for use of both IPv4 and IPv6. See IPv6 configuration
guidelines in OOB node management for information about platforms that support IPv6 for the OOB
management port.
See the 7210 SAS OS Software Release Notes 11.0Rx for information about the specific software release
that supports OOB management port and IPv6.
4.7.1 IPv6 configuration guidelines in OOB node management
The following are the configuration guidelines for IPv6 on an OOB management port of the node:
The management port on the management router instance only supports host functionality.
It is required that an IPv4 address is configured in the BOF. A BOF that contains only IPv6 addresses is
not supported.
IPv6 duplicate address detection is not supported.
IPv6 auto-configuration is not supported.
IPv6 over IPv4 tunneling is not supported.
IPv6 path MTU discovery is not supported.
The router discovery option is not supported on the management port.
4.8 Security for console port and Ethernet management port
The 7210 SAS OS supports disabling the console port and OOB Ethernet management port. In remote
deployments, operators can choose to disable user access to the node through the console and through
the Ethernet management port to prevent unauthorized and malicious access. Use the bof>console-
disabled command to disable the console and the bof>eth-mgmt-disabled command to disable the use
of the Ethernet management port.