7210 SAS-MXP, R6, R12, S, SX, T BASIC SYSTEM
CONFIGURATION GUIDE RELEASE 22.9.R1
System management
Parameters
file-url
Specifies the location and name of the CLI script file executed following failure of the boot-
up configuration file execution. When this parameter is not specified, no CLI script file is
executed.
Values file url — local-url | remote-url: 255 chars max
local-url — [cflash-id/ | usb-flash-id][file-path]
remote-url — [{ftp://} login:pswd@remote-locn/][file-path]
remote-locn — [hostname | ipv4-address]
ipv4-address — a.b.c.d
uf1: (7210 SAS-T, 7210 SAS-Mxp,
7210 SAS-Sx 1/10GE: standalone and
standalone-VC, and 7210 SAS-Sx 10/
100GE)
usb-flash-id
—
uf1:, uf1-A:, uf1-B: (7210 SAS-R6 and
7210 SAS-R12)
cf1:, cf2: (7210 SAS-T, 7210 SAS-Mxp,
7210 SAS-Sx 10/100GE, and 7210 SAS-Sx
1/10GE: standalone and standalone-VC)
cflash-id —
cf2:, cf2-A:, cf2-B: (7210 SAS-R6 and
7210 SAS-R12)
allow-imm-family
Syntax
allow-imm-family imm-family
no allow-imm-family
Context
config>system>chassis
Platforms
7210 SAS-R6 and 7210 SAS-R12
Description
This command allows the users to configure the type of IMM they plan to use with the chassis. The type of
IMM planned to be used in a chassis needs to be configured up-front, so that on system boot, the software
can allocate appropriate resources based on the IMM type.
The software checks that the IMMs provisioned (and equipped) in the chassis is a member of the IMM
family type currently configured (active value) by the user. If the user provisioned IMM does not match the
3HE 18197 AAAB TQZZA
© 2022 Nokia.
Use subject to Terms available at: www.nokia.com/terms/.
353