7210 SAS-MXP, R6, R12, S, SX, T BASIC SYSTEM
CONFIGURATION GUIDE RELEASE 22.9.R1
System management
Description
This command configures a stable frequency reference obtained through one of the line references (SyncE
or bits) for the PTP clock. This is achieved by specifying ssu to be the frequency source for PTP. This
mode of operation where PTP is used only for time recovery, and SyncE or BITS is used for frequency
recovery, is known as PTP hybrid mode.
If the frequency reference is set to ssu, PTP is running in hybrid mode (if PTP is also in a no shutdown
state) using the recovered frequency provided by the central clock through either of the configured
references (SyncE or BITS, whichever is configured as a reference for the central clock). In this setting,
PTP cannot be configured as a reference in the ref-order. The CLI blocks this configuration. The reverse is
also true; that is, if PTP is configured under ref-order, this parameter cannot be set to ssu.
If the frequency reference is set to ptp, PTP runs in pure mode, potentially being configured as a frequency
reference in ref-order.
Note:
See Configuration guidelines and restrictions for PTP for more information about command
usage.
The no form of this command reverts to the default value.
Default
freq-source ptp
Parameters
freq-source
Specifies whether PTP is used for frequency and time recovery, or only for time recovery. If
ptp is specified, PTP is used for both frequency and time recovery. If ssu is specified, PTP
is used only for time recovery.
Values ptp, ssu
clock-type
Syntax
clock-type boundary
clock-type ordinary slave
Context
config>system>ptp
Platforms
7210 SAS-Mxp, 7210 SAS-R6, 7210 SAS-R12, 7210 SAS-Sx 1/10GE (standalone), 7210 SAS-Sx
10/100GE 64SFP+ 4QSFP28 (standalone), 7210 SAS-T (network and access-uplink)
Description
This command configures the type of clock. The clock-type can only be changed when PTP is shutdown.