7210 SAS-MXP, R6, R12, S, SX, T BASIC SYSTEM
CONFIGURATION GUIDE RELEASE 22.9.R1
System management
When changing the clock-type to or from a boundary clock on the 7210 SAS-R6, 7210 SAS-R12,
7210 SAS-Mxp, and 7210 SAS-T platforms, the node must be rebooted for the change to take effect.
Default
ordinary slave
Parameters
boundary
Keyword to configure the clock as a boundary clock capable of functioning as both a
timeTransmitter and timeReceiver concurrently.
ordinary slave
Keyword to configure the clock as an ordinary PTP timeReceiver.
domain
Syntax
domain domain
no domain
Context
config>system>ptp
Platforms
7210 SAS-Mxp, 7210 SAS-R6, 7210 SAS-R12, 7210 SAS-Sx 1/10GE (standalone), 7210 SAS-Sx
10/100GE 64SFP+ 4QSFP28 (standalone), 7210 SAS-T (network and access-uplink)
Description
This command configures the PTP domain.
The domain cannot be modified unless PTP is shut down.
If the PTP profile is modified, the domain is changed to the default domain for the new PTP profile.
The no form of this command reverts to the default configuration.The default value depends on the
configured profile.
Default
0 for ieee1588-2008
4 for g8265dot1-2010
24 for g8275dot1-2014
Parameters
domain
Specifies the PTP domain.
3HE 18197 AAAB TQZZA