7210 SAS-MXP, R6, R12, S, SX, T BASIC SYSTEM
CONFIGURATION GUIDE RELEASE 22.9.R1
System management
Label Description
Line Coding The line coding configured for the BITS port
Line Length The line length value of the BITS output
Output Admin Status down — The BITS output is administratively shutdown
up — The BITS output is administratively enabled
diag — Indicates the BITS output has been forced using the
force-reference command
Output Reference
Selected
The reference selected as the source for the BITS output signal
(ref1 or ref2)
TX Quality Level QL value for BITS output signal
Quality Level Selection Indicates whether the ql-selection command has been enabled
or disabled
If this command is enabled, the reference is selected first
using the QL value, then by the priority reference order. If this
command is not enabled, the reference is selected by the priority
reference order.
System Quality Level Indicates the quality level being generated by the system clock
Rx Quality Level Indicates the QL value received on the interface
inv — SSM received on the interface indicates an invalid code
for the interface type
unknown — No QL value was received on the interface
script-control
Syntax
script-control
Context
show>system
Platforms
Supported on all 7210 SAS platforms as described in this document, including platforms configured in the
access-uplink operating mode
Description
Commands in this context display script information.
3HE 18197 AAAB TQZZA
© 2022 Nokia.
Use subject to Terms available at: www.nokia.com/terms/.
653