Creating / Running a CFR Application (Microsoft Access) SECTION 13 CFR (Title 21
207
13-4-9 Audit Trail Configuration Settings – Alarms Errors and Events
It is not necessary to invoke the Audit Trail Configuration dialog for auditing
points, but to generate an audit trail for alarms, errors and events the default
configuration state must be modified.
Launch the Audit Trail Configuration dialog.
Check the Log Alarm checkbox to allow logging of Alarms.
N.B. Logging of Alarms can be set to log ‘All Alarms’ or ‘Selected Alarms’. The
attribute to select any individual alarm is applied in the Alarms settings dialog
as described in the section below. ‘All Alarms’ when selected, overrides the
setting applied to individual alarms. ‘Selected Alarms’ setting will log to Audit
Trail only those Alarms with the ‘Generate Audit Trail’ attribute applied in the
Alarm Settings dialog.
Check the Log Errors/Events checkbox as shown below to allow Error and
Events to be logged into the Audit Trail.
Press OK to save these settings.
13-4-10 Configuring Alarms for Audit Trail Records
To demonstrate logging Alarms to the Audit Trail the CFR Test Project can be
modified as follows.

Table of Contents

Other manuals for Omron CX-Supervisor

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron CX-Supervisor and is the answer not in the manual?

Omron CX-Supervisor Specifications

General IconGeneral
BrandOmron
ModelCX-Supervisor
CategorySoftware
LanguageEnglish

Related product manuals